53
The information shown in Figure 29 below is one of the subsections available on the Advanced
Edit page.
Figure 29 – “LED Control” Interface on Advanced Edit page
This section gives you the ability to assume control of the PWR LED temporarily. This feature
can help you easily identify a specific card within a chassis if there is ever any doubt about
which card you are accessing. A brief explanation of each field shown above is as follows:
LED_State – This field allows you to control the PWR LED. This may be used as a simple
means to identify a particular card within a chassis at a remote location. The allowed values are:
0 = Off
1 = On
2 = Flashing
6.2.4 Reading the COM46 CAM Log Data